Retrieval of broken balloon from left anterior descending artery during percutaneous coronary intervention

Main Article Content

Bhardwaj Saurabh
Sharma Ruchi
Gupta LC
Yadav Uday Singh
Vinod Sharma*

Downloads

Download data is not yet available.

Article Details

Saurabh, B., Ruchi, S., LC, G., Singh, Y. U., & Sharma, V. (2022). Retrieval of broken balloon from left anterior descending artery during percutaneous coronary intervention. Global Journal of Medical and Clinical Case Reports, 9(4), 086–088. https://doi.org/10.17352/2455-5282.000166
Case Reports

Copyright (c) 2022 Saurabh B, et al.

Creative Commons License

This work is licensed under a Creative Commons Attribution 4.0 International License.

Kunwar BK, Jain P, Ghogare M. Catheter-Assisted Balloon-Supported Retrieval of a Broken Semi-Compliant Balloon from a Coronary Artery. J Clin Diagn Res. 2017 Mar;11(3):OD06-OD07. doi: 10.7860/JCDR/2017/24775.9580. Epub 2017 Mar 1. PMID: 28511441; PMCID: PMC5427367.

Patel T, Shah S, Pandya R, Sanghvi K, Fonseca K. Broken guidewire fragment: a simplified retrieval technique. Catheter Cardiovasc Interv. 2000 Dec;51(4):483-6. doi: 10.1002/1522-726x(200012)51:4<483::aid-ccd24>3.0.co;2-f. PMID: 11108687.

Singh J, Thingnam SK, Das D, Singh H, Sharma R, Vijayvergia R. Surgical removal of entrapped and broken percutaneous transluminal coronary angioplasty balloon catheter. Interact Cardiovasc Thorac Surg. 2007 Feb;6(1):94-6. doi: 10.1510/icvts.2006.140194. Epub 2006 Nov 22. PMID: 17669780.

Ancona MB, Giannini F, Jabbour RJ, Tanaka A, Regazzoli D, Mangieri A, Carlino M, Colombo A. Left main "Culotte in Culotte" to manage a trapped broken balloon. Int J Cardiol. 2016 Oct 15;221:347-9. doi: 10.1016/j.ijcard.2016.06.302. Epub 2016 Jun 29. PMID: 27404703.

Girish MP, Gupta MD, Mittal A. Percutaneous retrieval of entrapped partially inflated broken coronary angioplasty balloon by modified Fogarty technique. J Invasive Cardiol. 2011 Jul;23(7):E173-6. PMID: 21725135.

Mehta V, Pandit BN, Yusuf J, Mukhopadhyay S, Trehan V, Tyagi S. Retrieval of impacted broken balloon by balloon inflation in guiding catheter. Cardiovasc Interv Ther. 2014 Jul;29(3):252-5. doi: 10.1007/s12928-013-0221-9. Epub 2013 Nov 1. PMID: 24178859.